Patrick gets 5 stars - LBA gets 2 I am a disappointed and dissatisfied customer - you guys keep blowing it. Do I need to find another company. I’ve been loyal customer for many years. I’m hoping Tracey (manager) will call and take some responsibility on behalf of the sub par service of LBA.
LBA came for the annual a/c checkup today and did a thorough job. They called ahead, were on time, and explained everything to us.
For this job we augered a lavatory sink and a toilet. After we ran a water line from upstairs to the basement through the floor into the half inch cold. Thank you for choosing LBA
Arrived to do a dual system performance maintenance. Set each system for cooling. Measured the each systems static pressure measured a temperature split between return and supply air. Checked interior of the furnaces for cleanliness. Went outside and verified refrigerant levels for each separate system. Verified operation of all electronic and mechanical components. Found that the condenser fan for the main system has a delayed startup signaling a failure in the motor its self. Rinsed coils free of debris. Spoke with homeowner about the systems. Air conditioning systems are operational at this time.
For this job we were called out for 3 drain cleans and a water line to the refrigerator. 2 drain cleans were completed and drains were clear. The kitchen was suspected of needing a drain clearing. But with given information of when problem occurs. I determined that his kitchen line probably needs a vent to solve his solution. Customer has sewage extractor pump that kitchen line directly runs into. That pump is in fine order. 3yo. Thank you for choosing LBA!
Went for an out on system. Noticed condenser unit was over in dust and debris. After cleaning unit did check pressure are within range. Temp split is passing for system. All electrical components are passing. Had a dirty condenser causing for unit to struggle to remove heat from home. Thank you for choosing LBA services-Johann
Provided estimates for drain clearing and refrigerator water line.
Coil and condenser and cut 2 new vents in basement and replace Lineset needs 60ft
AC replacement and duct work modifications tomorrow. Thank you for choosing LBA services!
Went for an out. Tested for temp split and system was off by 4 degrees for minimum requirement. Filter was replaced as of today. Checked charge system is low and failing for manufacture specifications. Did clean condenser unit to help system breathe better. Noticed coil and rust and is the cause for the leak of refrigerant.System is up running before leaving. Thank you for choosing LBA services-Johann
Customer declined any repair options at this time. Too costly
Cleaned drain out. System is draining correctly. Thank you for choosing LBA services!